Dynamic fatigue testing machine
Electronic universal testing machine
Electro-hydraulic servo universal testing machine
Automated test scheme
Pendulum impact testing machine
Drop hammer impact testing machine
High temperature creep endurance testing machine
Horizontal testing machine
Special testing machine
Standard machine
Spring testing machine
Electric insulator testing machine
Fastener testing machine
Function summary:
TSV302 microcomputer-controlled thermal deformation Vica softening point testing machine equipment integration is high,The configuration of the implementation components and sensors make the equipment with high reliability, high temperature resistance, small deformation, sensitive response, accurate data transmission and other characteristics;The use of the equipment with the chiller can double the utilization rate of the equipment,The sample frame is made of low expansion coefficient alloy,Within 200℃, it can meet the standard requirements without correction。The machine is widely used for testing Vica softening temperature and load deformation temperature of thermoplastics and polymer materials。It is especially suitable for the production inspection, development and research of products and materials by pipe manufacturers, product quality checkpoints, construction engineering quality checkpoints, construction companies, scientific research institutions and other units。
Relevant standards:
GB/T8802-2001 Thermoplastic pipe, pipe fittings Vica softening temperature test
GB/T1633-2000 Thermoplastics Vica softening temperature (VST) determination
GB/T1634.1-2019 Plastics - Determination of deformation temperature under load - Part 1: General test methods
GB/T1634.2-2019 Plastics - Determination of deformation temperature under load - Part 2: Plastic ebonite and long fibre reinforced composites
D1525-00 Stand Test Method for Vicat Softening Temperture of Plastics
D648-01 Stand Test Method for Deflection of Plastics Under
Flexural Load in the Edgewiae Position
Equipment features:
The main sensors and execution components equipped with this machine have professional measurement performance of high quality and high reliability。
The thermal deformation temperature and Vica softening temperature can be tested simultaneously。
The initial cooling temperature is high, up to 280℃, which greatly improves the equipment utilization rate。
The sample frame has very little deformation under heat, and the deflection temperature without correction can reach 200℃。
The sample rack has automatic loading and automatic lifting functions, which eliminates manual handling of weights。
The fuel tank volume is reduced by more than 50% compared with the traditional equipment, which effectively reduces the user's use cost。
Technical parameters:
Specification and model | TSV302A | TSV302B | TSV302C |
Test station | 3 | 4 | 6 |
Temperature collection point | 3 | 4 | 6 |
Tank volume | 9L | 9L | 14L |
Cooling time | ≤45 minutes (280 ° C to 25 ° C, use with a chiller。) | ||
Cooling mode | 水冷 | ||
Load loading | 电动 | ||
Temperature control range | Ambient temperature ~300℃ | ||
Maximum temperature error | ±0.5℃ | ||
Deformation measuring range | 0mm to 10mm | ||
Deformation measurement resolution | 0.001mm | ||
Deformation measurement accuracy | 0.003mm | ||
Deflection without correction temperature | 20℃-200℃ | ||
VST Maximum sample size | 50mm×16mm×6.5mm (L×W×H) | ||
HDT maximum sample size | 130mm×15mm×13mm (L×W×H) | ||
HDT span | 64mm, 100mm, 65.6mm、101.6mm | ||
Vicar load | GA=10N±0.2N;GB=50N±1N | ||
Bending stress | 1.80MPa, 0.45MPa, 8.00MPa | ||
Rate of warming | (12 ±1)℃/ 6min [(120±10)℃/h] | ||
(5±0.5)℃/ 6min [(50±5)℃/h] | |||
Heating medium | 201 dimethylsilicone oil/Ambient temperature ~300℃(User provided) 10# transformer oil/Ambient temperature ~200℃(User provided) | ||
Heating power | 4.5kW | ||
电源 | 380V±10% 50Hz 5kW | ||
重量 | 115kg | 180kg |
Sweep for immediate attention
Copyright @ Shenzhen wance Test Equipment Co., Ltd. Copyright(C)2024 wance Technologies Ltd.
All Rights Reserved Guangdong ICP number 15055763